{"id":4274,"date":"2016-02-05T11:49:23","date_gmt":"2016-02-05T10:49:23","guid":{"rendered":"https:\/\/www.simlogic.pl\/?p=4274"},"modified":"2024-09-13T10:32:00","modified_gmt":"2024-09-13T08:32:00","slug":"opis-standardu-io-link","status":"publish","type":"post","link":"https:\/\/simlogic.pl\/en\/opis-standardu-io-link\/","title":{"rendered":"DESCRIPTION OF THE IO-LINK STANDARD"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;section&#8221; _builder_version=&#8221;4.16&#8243; global_colors_info=&#8221;{}&#8221;][et_pb_row admin_label=&#8221;row&#8221; _builder_version=&#8221;4.20.1&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; column_structure=&#8221;1_3,2_3&#8243; sticky_enabled=&#8221;0&#8243;][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_image src=&#8221;https:\/\/simlogic.pl\/wp-content\/uploads\/2023\/07\/ioqqq.png&#8221; _builder_version=&#8221;4.20.1&#8243; _module_preset=&#8221;default&#8221; title_text=&#8221;ioqqq&#8221; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243;][\/et_pb_image][\/et_pb_column][et_pb_column type=&#8221;2_3&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text _builder_version=&#8221;4.20.1&#8243; _module_preset=&#8221;default&#8221; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243; custom_margin=&#8221;25px||||false|false&#8221;]<\/p>\n<p>System IO-Link sk\u0142ada si\u0119 z urz\u0105dze\u0144 IO-Link- czujnik\u00f3w, si\u0142ownik\u00f3w, lub ich kombinacji: standardowego 3-przewodowego czujnika \/ kabla i urz\u0105dzenia IO Master. Urz\u0105dzenie typu master mo\u017ce posiada\u0107 ka\u017cdy wz\u00f3r i poziom ochrony. Master IO-Link mo\u017ce posiada\u0107 jeden lub kilka port\u00f3w. Tylko jedno urz\u0105dzenie IO-Link mo\u017ce by\u0107 pod\u0142\u0105czone do ka9dego portu. Tak wiec IO-Link jest komunikacja typu point to-point, a nie komunikacja typu fieldbus.<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.20.1&#8243; _module_preset=&#8221;default&#8221;][et_pb_column _builder_version=&#8221;4.20.1&#8243; _module_preset=&#8221;default&#8221; type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;4.20.1&#8243; _module_preset=&#8221;default&#8221; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243;]<\/p>\n<p>Na pocz\u0105tku urz\u0105dzenie jest zawsze w trybie SIO (Standard IO). Porty urz\u0105dzenia master mog\u0105 mie\u0107 r\u00f3\u017cne konfiguracje. Je\u017celi port jest ustawiony na tryb SIO, urz\u0105dzenie master na tym porcie dzia\u0142a jak zwyk\u0142e wej\u015bcie cyfrowe. Je\u017celi port jest ustawiony w trybie komunikacji, master pr\u00f3buje odnale\u017a\u0107 pod\u0142\u0105czone urz\u0105dzenie IO-Link. Ten proces nazywany jest wake-up (budzenie). Podczas procesu budzenia master wysy\u0142a okre\u015blony sygna\u0142, i czeka na odpowied\u017a urz\u0105dzenia. Master pr\u00f3buje zrobi\u0107 to z najwy\u017csza z okre\u015blonych szybko\u015bci transmisji. W razie niepowodzenia master pr\u00f3buje kolejnych ni\u017cszych szybko\u015bci transmisji. Przy ka\u017cdej szybko\u015bci transmisji master trzykrotnie sprawdza adres urz\u0105dzenia. Je\u017celi master otrzymuje odpowiedz (tzn. urz\u0105dzenie zosta\u0142o \u201eobudzone\u201d), rozpoczyna si\u0119 komunikacja. Najpierw nast\u0119puje wymiana parametr\u00f3w komunikacyjnych, a nast\u0119pnie rozpoczyna si\u0119 cykliczna wymiana danych procesowych. Je\u017celi w trakcie pracy urz\u0105dzenie zostanie od\u0142\u0105czone, master wykrywa przerwanie komunikacji, raportuje je (co charakterystyczne jest dla komunikacji typu Fieldbus) do systemu kontroli, i cyklicznie przyst\u0119puje do \u201ebudzenia\u201d urz\u0105dzenia. Po kolejnym udanym \u201ebudzeniu\u201d urz\u0105dzenia parametry komunikacji zostan\u0105 na nowo odczytane i zatwierdzone, i je\u015bli to konieczne, uruchomiona zostanie cykliczna wymiana danych. Je\u017celi master ko\u0144czy komunikacje, zar\u00f3wno master i urz\u0105dzenia powracaj\u0105 do pocz\u0105tkowego trybu SIO. Proces ten nosi nazw\u0119 \u201efall back\u201d.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.20.1&#8243; _module_preset=&#8221;default&#8221; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243; custom_margin=&#8221;40px|||||&#8221;]<\/p>\n<p>Opracowanie: PROFIBUS International; www.profibus.com<br \/>T\u0142umaczenie: PNO PROFIBUS PNO Polska; www.profibus.org.pl<br \/>Rozpowszechnianie i promocja: PICC &#8211; Centrum Kompetencyjne Sieci Przemys\u0142owych SIMLOGIC. ; www.simlogic.pl<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; min_height=&#8221;51px&#8221; custom_margin=&#8221;40px|||||&#8221;]<\/p>\n<p><a href=\"https:\/\/simlogic.pl\/en\/download\/opis-standardu-io-link\/\" title=\"DESCRIPTION OF THE IO-LINK STANDARD\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.simlogic.pl\/wp-content\/uploads\/2020\/04\/pdf.png\" width=\"50\" height=\"50\" alt=\"\" class=\"wp-image-421 alignnone size-full\" srcset=\"https:\/\/simlogic.pl\/wp-content\/uploads\/2020\/04\/pdf.png 128w, https:\/\/simlogic.pl\/wp-content\/uploads\/2020\/04\/pdf-100x100.png 100w\" sizes=\"(max-width: 50px) 100vw, 50px\" \/><a  data-e-disable-page-transition=\"true\" class=\"download-link\" title=\"\" href=\"https:\/\/simlogic.pl\/en\/download\/opis-standardu-io-link\/?tmstv=1776974197\" rel=\"nofollow\" id=\"download-link-4494\" data-redirect=\"false\" >\n\tOPIS STANDARDU IO-LINK\t(1982 downloads\t)\n<\/a>\n<\/a><\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>","protected":false},"excerpt":{"rendered":"<p>System IO-Link sk\u0142ada si\u0119 z urz\u0105dze\u0144 IO-Link- czujnik\u00f3w, si\u0142ownik\u00f3w, lub ich kombinacji: standardowego 3-przewodowego czujnika \/ kabla i urz\u0105dzenia IO Master. Urz\u0105dzenie typu master mo\u017ce posiada\u0107 ka\u017cdy wz\u00f3r i poziom ochrony. Master IO-Link mo\u017ce posiada\u0107 jeden lub kilka port\u00f3w. Tylko jedno urz\u0105dzenie IO-Link mo\u017ce by\u0107 pod\u0142\u0105czone do ka9dego portu. Tak wiec IO-Link jest komunikacja typu [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"<!-- wp:image {\"id\":4497,\"width\":404,\"height\":278,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\n<figure class=\"wp-block-image size-full is-resized\"><img src=\"https:\/\/www.simlogic.pl\/wp-content\/uploads\/2021\/08\/ioqqq.png\" alt=\"\" class=\"wp-image-4497\" width=\"404\" height=\"278\"\/><\/figure>\n<!-- \/wp:image -->\n\n<!-- wp:paragraph -->\n<p>System IO-Link sk\u0142ada si\u0119 z urz\u0105dze\u0144 IO-Link- czujnik\u00f3w, si\u0142ownik\u00f3w, lub ich kombinacji: standardowego 3-przewodowego czujnika \/ kabla i urz\u0105dzenia IO Master. Urz\u0105dzenie typu master mo\u017ce posiada\u0107 ka\u017cdy wz\u00f3r i poziom ochrony. Master IO-Link mo\u017ce posiada\u0107 jeden lub kilka port\u00f3w. Tylko jedno urz\u0105dzenie IO-Link mo\u017ce by\u0107 pod\u0142\u0105czone do ka9dego portu. Tak wiec IO-Link jest komunikacja typu point to-point, a nie komunikacja typu fieldbus.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p>Na pocz\u0105tku urz\u0105dzenie jest zawsze w trybie SIO (Standard IO). Porty urz\u0105dzenia master mog\u0105 mie\u0107 r\u00f3\u017cne konfiguracje. Je\u017celi port jest ustawiony na tryb SIO, urz\u0105dzenie master na tym porcie dzia\u0142a jak zwyk\u0142e wej\u015bcie cyfrowe. Je\u017celi port jest ustawiony w trybie komunikacji, master pr\u00f3buje odnale\u017a\u0107 pod\u0142\u0105czone urz\u0105dzenie IO-Link. Ten proces nazywany jest wake-up (budzenie). Podczas procesu budzenia master wysy\u0142a okre\u015blony sygna\u0142, i czeka na odpowied\u017a urz\u0105dzenia. Master pr\u00f3buje zrobi\u0107 to z najwy\u017csza z okre\u015blonych szybko\u015bci transmisji. W razie niepowodzenia master pr\u00f3buje kolejnych ni\u017cszych szybko\u015bci transmisji. Przy ka\u017cdej szybko\u015bci transmisji master trzykrotnie sprawdza adres urz\u0105dzenia. Je\u017celi master otrzymuje odpowiedz (tzn. urz\u0105dzenie zosta\u0142o \u201eobudzone\u201d), rozpoczyna si\u0119 komunikacja. Najpierw nast\u0119puje wymiana parametr\u00f3w komunikacyjnych, a nast\u0119pnie rozpoczyna si\u0119 cykliczna wymiana danych procesowych. Je\u017celi w trakcie pracy urz\u0105dzenie zostanie od\u0142\u0105czone, master wykrywa przerwanie komunikacji, raportuje je (co charakterystyczne jest dla komunikacji typu Fieldbus) do systemu kontroli, i cyklicznie przyst\u0119puje do \u201ebudzenia\u201d urz\u0105dzenia. Po kolejnym udanym \u201ebudzeniu\u201d urz\u0105dzenia parametry komunikacji zostan\u0105 na nowo odczytane i zatwierdzone, i je\u015bli to konieczne, uruchomiona zostanie cykliczna wymiana danych. Je\u017celi master ko\u0144czy komunikacje, zar\u00f3wno master i urz\u0105dzenia powracaj\u0105 do pocz\u0105tkowego trybu SIO. Proces ten nosi nazw\u0119 \u201efall back\u201d.<br><br>Opracowanie: PROFIBUS International; www.profibus.com<br>T\u0142umaczenie: PNO PROFIBUS PNO Polska; www.profibus.org.pl<br>Rozpowszechnianie i promocja: PICC - Centrum Kompetencyjne Sieci Przemys\u0142owych SIMLOGIC. ; www.simlogic.pl<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p> <\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:columns -->\n<div class=\"wp-block-columns\"><!-- wp:column {\"width\":\"100%\"} -->\n<div class=\"wp-block-column\" style=\"flex-basis:100%\"><!-- wp:group -->\n<div class=\"wp-block-group\"><!-- wp:file {\"id\":4275,\"href\":\"https:\/\/www.simlogic.pl\/wp-content\/uploads\/2021\/04\/opisstandarduio_link.pdf\"} -->\n<div class=\"wp-block-file\"><a href=\"https:\/\/www.simlogic.pl\/wp-content\/uploads\/2021\/04\/opisstandarduio_link.pdf\"><img class=\"wp-image-421\" style=\"width: 40px;\" src=\"https:\/\/www.simlogic.pl\/wp-content\/uploads\/2020\/04\/pdf.png\" alt=\"\">opisstandarduio_link<\/a><a href=\"https:\/\/www.simlogic.pl\/wp-content\/uploads\/2021\/04\/opisstandarduio_link.pdf\" class=\"wp-block-file__button\" download>Pobierz<\/a><\/div>\n<!-- \/wp:file --><\/div>\n<!-- \/wp:group --><\/div>\n<!-- \/wp:column --><\/div>\n<!-- \/wp:columns -->\n\n<!-- wp:paragraph -->\n<p><\/p>\n<!-- \/wp:paragraph -->","_et_gb_content_width":"","footnotes":""},"categories":[3,18,21],"tags":[],"class_list":["post-4274","post","type-post","status-publish","format-standard","hentry","category-baza-wiedzy","category-iolink","category-komunikacja"],"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/simlogic.pl\/en\/wp-json\/wp\/v2\/posts\/4274","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/simlogic.pl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/simlogic.pl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/simlogic.pl\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/simlogic.pl\/en\/wp-json\/wp\/v2\/comments?post=4274"}],"version-history":[{"count":9,"href":"https:\/\/simlogic.pl\/en\/wp-json\/wp\/v2\/posts\/4274\/revisions"}],"predecessor-version":[{"id":5295,"href":"https:\/\/simlogic.pl\/en\/wp-json\/wp\/v2\/posts\/4274\/revisions\/5295"}],"wp:attachment":[{"href":"https:\/\/simlogic.pl\/en\/wp-json\/wp\/v2\/media?parent=4274"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/simlogic.pl\/en\/wp-json\/wp\/v2\/categories?post=4274"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/simlogic.pl\/en\/wp-json\/wp\/v2\/tags?post=4274"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}